Current Transducer

NA100-P Current Transducer

Ningbo CRRC

NA100-P  Current Transducer

1,400.00

QuantityBulk Purchase Pricing
1 - 499 1400 Price Per Item
500 - 999 1290 Price Per Item

Awaiting for Delivery

SKU: NA100-P Categories: , Tag:

Description

Main  technical data:

1. Primary normal current IPN: 100A r.m.s
2. Primary current, measuring range IP: 0~+/-150A
3. Measuring resistance: RMmin RMmax with +/-12V @ +/-100A max: 0 ohm 42 ohm @ +/-120A max: 0 ohm 14  ohm with +/-15V @ +/-100A max: 20 ohm 100 ohm @ +/-150A max: 20 ohm 25 ohm
4. Secondary normal current: 50mA rms
5. Conversion ratio: 1:2000
6. Supply voltage(+/-5%): +/-12V~+/-15V
7. Current consumption: 10mA+ Secondary output current
8. Isolation test: Between the primary circuit to the secondary circuit: 2.5kVrms/50Hz/1min Accuracy – Dynamic

Performance data:

1. Accuracy @ IPN, TA=+25 oC , @+/-12V~+/-15V: +/-0.7%
2. Non-linearity: better than +/-0.2%
3. Offset current: not more than +/-0.1mA(@+25oC)
4. Residual current @ IP=0 after an overload of 3xIP: +/-0.3mA
5. Thermal drift: +/-0.25mA(-25 oC ~+85 oC) +/-0.50mA(-40 oC ~+25 oC)
6. Reaction time @10% of IP max : less than 500ns
7. Response time: not more than 1us
8. di/dt accurately followed: better than 100A/us
9. Frequency Bandwidth (0.5dB): DC 0~200kHz

General data:

1. Operating temperature: -40ºC~+85ºC
2. Storage temperature: -40 oC ~+90 oC
3. Secondary coil resistance: not more than 120 ohm